4
Capacitive coupling
Inductive coupling
Radiative coupling
Common impedance coupling
Conductive coupling
To prevent EMI, take the following actions:
Take measures against interference from the power grid.
Do not use the router together with the grounding equipment or lightning-prevention equipment of
power equipment, and keep the router far away from them.
Keep the router far away from high-power radio launchers, radars, and equipment with high
frequency or high current.
Use electromagnetic shielding when necessary.
Lightning protection
To better protect the router from lightning, do as follows:
Make sure the grounding cable of the chassis is correctly grounded.
Make sure the grounding terminal of the AC power receptacle is correctly grounded.
Install a lightning arrester at the input end of the power supply to enhance the lightning protection
capability of the power supply.
Install a special lightning arrester at the input end of outdoor signal lines (for example, E1/T1 line)
to which interface modules of the router are connected to enhance the lightning protection
capability.
Rack-mounting
Before mounting the router in a rack, adhere to the following requirements:
The rack is equipped with a good ventilation system.
The rack is sturdy enough to support the router and its accessories.
For heat dissipation and device maintenance, make sure the front and rear of the rack are at least
0.8 m (2.62 ft) away from walls or other devices, and the headroom in the equipment room is no
less than 3 m (9.84 ft).